Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13678044

- Product Categories
- Friendly Links
- home > Supply > Supply Omron Relay G5NB-1A, power relays, quality assurance, fake a compensable 10, original authentic
Supply Omron Relay G5NB-1A, power relays, quality assurance, fake a compensable 10, original authentic
Information Name: | Supply Omron Relay G5NB-1A, power relays, quality assurance, fake a compensable 10, original authentic |
Published: | 2015-04-21 |
Validity: | 30 |
Specifications: | |
Quantity: | 1000000.00 |
Price Description: | |
Detailed Product Description: | G5NB series is impact-resistant voltage of 10kV a very small opening and closing relays 3A, specifications 20.5 * 7.2 * 15.3mm G5NB series features a small relay, but there it is possible to ensure the withstand voltage of 10kV;. Using a high-power electromagnetic circuit achieve high sensitivity (200mW) and reinforced insulation purposes in line with standard EN61010. G5NB-1A reference parameters constitute the type of species protection project contact structure models rated coil voltage (V) Minimum packing unit monostable type 1a resistant flux G5NB-1A DC 5 100 cells / tray DC12 DC18 DC24 Note. When ordering, please indicate the coil Rated voltage (V). For example: G5NB-1A DC5 rated operating rated coil voltage (V) Rated current project _ coil resistance (iv) operating voltage reset voltage (V) Maximum allowable voltage (V) Power consumption (mW) (V) DC 5 40 125 75% or less more than 10% 180% (at23r> approximately 20 012 16.7 72 018 11.1 24 8.3 1,620 2,880 Note 1. The rated current and coil resistance coil temperature of +23 ℃: value, the tolerance of ± 10% Note 2. The operating characteristics. a coil temperature value at +23 ℃ time. Note 3. The maximum allowable voltage is the maximum value of the relay coil capable of applying a voltage switch portion (contact portion) projects resistive load contact mechanism Single contact material Ag alloy (Cd-free material) Rated load AC125V 3A DC30V 3A maximum contact voltage AC250V, DC30V contact maximum 3A current performance contact resistance * 1 lOOmΩ less operating time reset time 10ms or less 10ms or less Insulation resistance * 2 1,000MΩ above (DC500V megger) Pressure between coil and contacts AC4,000V 50 / 60Hz lmin with the inter-electrode contact AC750V 50 / 60Hz lmin withstand voltage between coil and contacts 10kV (1.2X50ns) vibration durable 10? 55? 10Hz single amplitude 0.75mm (double amplitude 1.5mm) error Action 10? 55? 10Hz single amplitude 0.75mm (double amplitude 1.5mm) impact durable l, 000m / s2 malfunction 100m / s2 more than 5 million times the life of a mechanical air more than 20 million times (rated load switching frequency of 1,800 times / h ) failure rate P level (reference value * 3) DC5V 10mA Ambient temperature -40 ~ + 70 ℃ :( no icing or condensation) Operating Humidity 5? 85% RH weight of about 4g Note above the initial value * 1. Measurement conditions: According to the voltage drop method * 2 Measured at DC5V1A conditions: DC500V megger measurement, the same position with the measured voltage * 3 This is the switching frequency of 120 times / min.. value. |
Admin>>>
You are the 8499 visitor
Copyright © GuangDong ICP No. 10089450, Lin Electronics Co., Ltd., Dongguan trickle All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8499 visitor
Copyright © GuangDong ICP No. 10089450, Lin Electronics Co., Ltd., Dongguan trickle All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility