Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13678044

- Product Categories
- Friendly Links
Information Name: | | Supply Omron Relay G5RL-1A-E▋ power relays, Omron, telephone 13422543390 |
Published: | 2015-04-01 |
Validity: | 30 |
Specifications: | |
Quantity: | 1000000.00 |
Price Description: | |
Detailed Product Description: | Contact constitute species classification Terminal shape Coil voltage protection structure model [V] minimum packing unit resistant high capacity type printed circuit board terminal SPDT (1C) Flux type G5RL-1A-E AC24V, AC100V, AC155V / AC120V, AC220V, AC230V / AC240V 100 pcs / pallet note. When ordering, please indicate the rated coil voltage (V). For example: G5RL-1A-E DC5V Ratings Rated voltage (v) rated voltage at 50Hz (ma) of rated voltage at 60Hz (ma) coil resistance movement voltage (V) reset voltage (v) the maximum allowable voltage (v) Consumption Power (Mw) AC24V 31.3 28.3 443 110% 15% 75% of rated voltage rated voltage below the rated voltage of less than about 750 AC100V 75 6.88 8220 AC115V / 120 5.85 / 6.25 5.35 / 5.70 11600 AC200 3.75 3.45 33000 AC230 / 240 2003 -3-13 2.76 / 2.88 57600 Note: 1 rated current and coil resistance of the coil temperature +23 ℃ when the tolerance + 15% -20%. 2 coil resistance reference value. Contact the Department of positive load is high capacity type load contact form SPDT (1C) contact structure of single Ag alloy contact material rated load AC250V, DC24V (NO) 16A AC250V, DC24V (N0 / NC) 5A rated thermal current 16A (NO), 5A (NC ) Maximum switching voltage AC250V, DC24V maximum switching current 16A (NO), 5A (NC) Performance Project types of high capacity type contact resistance 100mΩ less operating time below 200ms reset time below 200ms Insulation resistance 1,000mΩ above (DC500V) voltage coil and contacts between AC6,000V 1mA 50 / 60Hz lmin with inter-electrode contact AC1,000V 1mA 50 / 60Hz lmin impact resistance between coil and contact voltage 10kV (1.2 * 50us) vibration durable 10? 55? 10Hz single amplitude 0.75mm (1.5mm double amplitude ) malfunction 10? 55? 10Hz single amplitude 0.75mm (double amplitude 1.5mm) impact durability 1.000m / s2 malfunction 1.00m / s2 mechanical life over one million times (switching frequency of 18,000 times / hr) Electrical 100,000 times more (switching frequency 720 times / hr) using bad Terrier temperature -40 ~ + 80 ℃ :( no icing or condensation) Operating Humidity 5? 85% RH Weight Approx 10g Note 1 above the initial value * Measurement Conditions: according to the voltage drop method, the conditions under DC5V 1A. * 2 Measurement conditions: with DC500V megger, or between coil and contacts between the pole contacts in the same measure. * 3. When the NC contact with no load, resistive load value NO contact. |
Admin>>>
You are the 8499 visitor
Copyright © GuangDong ICP No. 10089450, Lin Electronics Co., Ltd., Dongguan trickle All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8499 visitor
Copyright © GuangDong ICP No. 10089450, Lin Electronics Co., Ltd., Dongguan trickle All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility